Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Length of sensor
44mm
Diameter sensor
0mm
Switching function latching
No
Switching function
Slow-action switch
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Type of interface
None
Height of sensor
77mm
Width sensor
40mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
2
Number of safety auxiliary contacts
0
Forced opening
Yes
Output electronic
No
Rated operation current Ie at AC-15, 230 V
1.5A
Suitable for safety functions
No
With status indication
No
Explosion safety category for dust
None
Alignment of the control element
Other
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 - 70°C
Rated operation current Ie at DC-13, 230 V
0.1A
Material housing
Metal
Type of control element
None
Coating housing
Other
Explosion safety category for gas
None
Degree of protection (IP)
IP65
ZCKJD37H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Length of sensor
44mm
Diameter sensor
0mm
Switching function latching
Switching function
Slow-action switch
Number of contacts as normally open contact
1
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Type of interface
None
Height of sensor
77mm
Width sensor
40mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
2
Number of safety auxiliary contacts
0
Forced opening
Output electronic
Rated operation current Ie at AC-15, 230 V
1.5A
Suitable for safety functions
With status indication
Explosion safety category for dust
None
Alignment of the control element
Other
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 .. 70°C
Rated operation current Ie at DC-13, 230 V
0.1A
Material housing
Metal
Type of control element
None
Coating housing
Other
Explosion safety category for gas
None
Degree of protection (IP)
IP65