Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
51mm
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at DC-13, 24 V
0A
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Width sensor
58mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Length of sensor
30mm
Switching function
Slow-action switch with overlapping
Number of safety auxiliary contacts
0
Forced opening
Yes
Number of contacts as normally closed contact
1
Switching function latching
No
Output electronic
No
Rated operation current Ie at DC-13, 125 V
0A
Type of interface
None
Construction type housing
Cuboid
Material housing
Plastic
Alignment of the control element
Other
Coating housing
Other
Explosion safety category for gas
None
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
Explosion safety category for dust
None
Suitable for safety functions
No
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Type of interface for safety communication
None
Type of control element
None
With status indication
No
Type of electric connection
Cable entry metrical
ZCT26P16

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
51mm
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at DC-13, 24 V
0A
Diameter sensor
0mm
Rated operation current Ie at AC-15, 24 V
0A
Width sensor
58mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Length of sensor
30mm
Switching function
Slow-action switch with overlapping
Number of safety auxiliary contacts
0
Forced opening
Number of contacts as normally closed contact
1
Switching function latching
Output electronic
Rated operation current Ie at DC-13, 125 V
0A
Type of interface
None
Construction type housing
Cuboid
Material housing
Plastic
Alignment of the control element
Other
Coating housing
Other
Explosion safety category for gas
None
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
Explosion safety category for dust
None
Suitable for safety functions
Number of contacts as normally open contact
1
Number of contacts as change-over contact
0
Type of interface for safety communication
None
Type of control element
None
With status indication
Type of electric connection
Cable entry metrical