Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Voltage type of supply voltageDC
Number of HW-interfaces other1
Height74.1mm
Number of analogue inputs1
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet0
Width12.6mm
Suitable for safety functionsNo
Number of HW-interfaces USB0
Depth55.4mm
Number of analogue outputs0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Explosion safety category for gasNone
Output signal configurableNo
Supporting protocol for CANNo
Input, voltageYes
Rail mounting possibleYes
Input, thermocoupleNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Resolution of the analogue outputs0Bit
Type of electric connectionScrew-/spring clamp connection
Supporting protocol for Data-HighwayNo
Input signal, configurableYes
Supporting protocol for other bus systemsYes
Input, resistance thermometerNo
Resolution of the analogue inputs16Bit
Output, voltageNo
Input, currentNo
Input, resistorNo
Explosion safety category for dustNone
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Output, currentNo
Appendant operation agent (Ex ib)No
Wall mounting/direct mountingNo
IO link masterNo
Degree of protection (IP)IP20
Supporting protocol for DeviceNet SafetyNo
Number of interfaces PROFINET0
Performance level according to EN ISO 13849-1None
Radio standard Wi-Fi 802.11No
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Front built-in possibleNo
Radio standard BluetoothNo
Rack-assembly possibleNo
Supporting protocol for INTERBUS-SafetyNo
Appendant operation agent (Ex ia)No
Supply voltage DC20.4 - 28.8V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherCATNo
Analogue inputs configurableYes
Degree of protection (NEMA)1
Radio standard GPRSNo
Radio standard UMTSNo
Certified for UL hazardous location class INo
SIL according to IEC 61508None
Analogue outputs configurableYes
Radio standard GSMNo
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 2No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group A (acetylene)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

XN-1AI-U(-10/0...+10VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Voltage type of supply voltage

DC

Number of HW-interfaces other

1

Height

74.1mm

Number of analogue inputs

1

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Width

12.6mm

Suitable for safety functions

Number of HW-interfaces USB

0

Depth

55.4mm

Number of analogue outputs

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Explosion safety category for gas

None

Output signal configurable

Supporting protocol for CAN

Input, voltage

Rail mounting possible

Input, thermocouple

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Resolution of the analogue outputs

0Bit

Type of electric connection

Screw-/spring clamp connection

Supporting protocol for Data-Highway

Input signal, configurable

Supporting protocol for other bus systems

Input, resistance thermometer

Resolution of the analogue inputs

16Bit

Output, voltage

Input, current

Input, resistor

Explosion safety category for dust

None

Fieldbus connection over separate bus coupler possible

System accessory

Output, current

Appendant operation agent (Ex ib)

Wall mounting/direct mounting

IO link master

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet Safety

Number of interfaces PROFINET

0

Performance level according to EN ISO 13849-1

None

Radio standard Wi-Fi 802.11

Number of HW-interfaces Wireless

0

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Front built-in possible

Radio standard Bluetooth

Rack-assembly possible

Supporting protocol for INTERBUS-Safety

Appendant operation agent (Ex ia)

Supply voltage DC

20.4 .. 28.8V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for EtherCAT

Analogue inputs configurable

Degree of protection (NEMA)

1

Radio standard GPRS

Radio standard UMTS

Certified for UL hazardous location class I

SIL according to IEC 61508

None

Analogue outputs configurable

Radio standard GSM

Certified for UL hazardous location class II

Certified for UL hazardous location division 2

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location division 1

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location class III

Certified for UL hazardous location group A (acetylene)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.