  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other0
Supporting protocol for LONNo
Width107mm
Number of HW-interfaces parallel0
Height231mm
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of analogue inputs2
Number of digital outputs1
Number of HW-interfaces RS-2320
With control elementYes
Depth152mm
Power consumption63W
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of analogue outputs1
Number of digital inputs4
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
Mains voltage200 - 240V
Max. output frequency500Hz
4-quadrant operation possibleYes
Integrated breaking resistanceYes
Number of phases output3
Supporting protocol for SUCONETNo
Max. output at quadratic load at rated output voltage1.5kW
Number of interfaces PROFINET0
Number of phases input1
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Mains frequency50/60 Hz
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage1.5kW
Type of converterU converter
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)Other
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N7A
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Max. output voltage250V
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-127D0FB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other

0

Supporting protocol for LON

Width

107mm

Number of HW-interfaces parallel

0

Height

231mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of analogue inputs

2

Number of digital outputs

1

Number of HW-interfaces RS-232

0

With control element

Depth

152mm

Power consumption

63W

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of analogue outputs

1

Number of digital inputs

4

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for ASI

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

With PC connection

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for other bus systems

Mains voltage

200 .. 240V

Max. output frequency

500Hz

4-quadrant operation possible

Integrated breaking resistance

Number of phases output

3

Supporting protocol for SUCONET

Max. output at quadratic load at rated output voltage

1.5kW

Number of interfaces PROFINET

0

Number of phases input

1

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

1.5kW

Type of converter

U converter

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

Other

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Nominal output current I2N

7A

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Max. output voltage

250V

Supporting protocol for BACnet