  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width107mm
Height231mm
Power consumption63W
Number of analogue outputs1
Number of analogue inputs2
With control elementYes
Number of digital outputs1
Depth152mm
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of digital inputs4
Number of HW-interfaces other0
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Mains voltage200 - 240V
Supporting protocol for SERCOSNo
With PC connectionYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
Number of phases output3
4-quadrant operation possibleYes
Application in industrial area permittedYes
Max. output frequency500Hz
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Number of phases input1
Integrated breaking resistanceYes
Application in domestic- and commercial area permittedYes
Type of converterU converter
Max. output at quadratic load at rated output voltage1.5kW
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N7A
Degree of protection (NEMA)Other
Supporting protocol for Foundation FieldbusNo
Max. output voltage250V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-127D0NB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

107mm

Height

231mm

Power consumption

63W

Number of analogue outputs

1

Number of analogue inputs

2

With control element

Number of digital outputs

1

Depth

152mm

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

4

Number of HW-interfaces other

0

Supporting protocol for LON

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Mains voltage

200 .. 240V

Supporting protocol for SERCOS

With PC connection

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Number of phases output

3

4-quadrant operation possible

Application in industrial area permitted

Max. output frequency

500Hz

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Number of phases input

1

Integrated breaking resistance

Application in domestic- and commercial area permitted

Type of converter

U converter

Max. output at quadratic load at rated output voltage

1.5kW

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Nominal output current I2N

7A

Degree of protection (NEMA)

Other

Supporting protocol for Foundation Fieldbus

Max. output voltage

250V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Related products