Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs4
Power consumption63W
Number of digital outputs1
Number of HW-interfaces industrial Ethernet0
Depth124mm
Width81mm
With control elementYes
Supporting protocol for LONNo
Number of analogue outputs1
Number of analogue inputs2
Height184mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Supporting protocol for SERCOSNo
Number of HW-interfaces RS-4220
With PC connectionYes
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other0
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for ModbusYes
Number of HW-interfaces USB0
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Mains voltage200 - 240V
Application in domestic- and commercial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases output3
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage1.5kW
Relative symmetric net frequency tolerance10%
Number of phases input1
4-quadrant operation possibleNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output at linear load at rated output voltage1.5kW
Application in industrial area permittedYes
Nominal output current I2N7A
Max. output voltage250V
Integrated breaking resistanceNo
Type of converterU converter
Max. output frequency500Hz
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
Number of interfaces PROFINET0
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-127D0NN-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

4

Power consumption

63W

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

0

Depth

124mm

Width

81mm

With control element

Supporting protocol for LON

Number of analogue outputs

1

Number of analogue inputs

2

Height

184mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Supporting protocol for SERCOS

Number of HW-interfaces RS-422

0

With PC connection

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Number of HW-interfaces other

0

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for Modbus

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Mains voltage

200 .. 240V

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Number of phases output

3

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

1.5kW

Relative symmetric net frequency tolerance

10%

Number of phases input

1

4-quadrant operation possible

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output at linear load at rated output voltage

1.5kW

Application in industrial area permitted

Nominal output current I2N

7A

Max. output voltage

250V

Integrated breaking resistance

Type of converter

U converter

Max. output frequency

500Hz

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Number of interfaces PROFINET

0

Supporting protocol for EtherNet/IP

Degree of protection (NEMA)

Other

Related products