Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other0
Number of digital inputs4
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Height231mm
With control elementYes
Width107mm
Depth152mm
Number of HW-interfaces USB0
Power consumption61.5W
Number of digital outputs1
Number of HW-interfaces RS-4851
Number of analogue inputs2
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Number of analogue outputs1
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for Data-HighwayNo
Mains voltage200 - 240V
Supporting protocol for SERCOSNo
Type of converterU converter
Number of phases output3
Supporting protocol for KNXNo
Mains frequency50/60 Hz
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Degree of protection (IP)IP20
4-quadrant operation possibleYes
Supporting protocol for ASINo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSNo
Number of phases input3
Application in industrial area permittedYes
Max. output frequency500Hz
Integrated breaking resistanceYes
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Nominal output current I2N7A
Max. output voltage250V
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-327D0FB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other

0

Number of digital inputs

4

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Height

231mm

With control element

Width

107mm

Depth

152mm

Number of HW-interfaces USB

0

Power consumption

61.5W

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Number of analogue inputs

2

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Supporting protocol for LON

Number of analogue outputs

1

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for other bus systems

With PC connection

Supporting protocol for Data-Highway

Mains voltage

200 .. 240V

Supporting protocol for SERCOS

Type of converter

U converter

Number of phases output

3

Supporting protocol for KNX

Mains frequency

50/60 Hz

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

4-quadrant operation possible

Supporting protocol for ASI

Supporting protocol for INTERBUS-Safety

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Number of phases input

3

Application in industrial area permitted

Max. output frequency

500Hz

Integrated breaking resistance

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Nominal output current I2N

7A

Max. output voltage

250V

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Supporting protocol for BACnet

Related products