Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Depth175mm
Number of digital inputs4
Width129mm
Number of HW-interfaces RS-2320
Number of analogue outputs1
With control elementYes
Number of HW-interfaces industrial Ethernet0
Number of digital outputs1
Supporting protocol for LONNo
Power consumption297W
Height273mm
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Number of phases input3
Mains voltage380 - 480V
Number of phases output3
Type of converterU converter
With PC connectionYes
Supporting protocol for Data-HighwayNo
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Degree of protection (IP)IP20
With optical interfaceNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
4-quadrant operation possibleYes
Supporting protocol for SUCONETNo
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Integrated breaking resistanceYes
Max. output at quadratic load at rated output voltage11kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Max. output at linear load at rated output voltage11kW
Relative symmetric net voltage tolerance10%
Max. output voltage500V
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetNo
Nominal output current I2N24A
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34024FB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Depth

175mm

Number of digital inputs

4

Width

129mm

Number of HW-interfaces RS-232

0

Number of analogue outputs

1

With control element

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

1

Supporting protocol for LON

Power consumption

297W

Height

273mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Supporting protocol for ASI

Supporting protocol for KNX

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Number of phases input

3

Mains voltage

380 .. 480V

Number of phases output

3

Type of converter

U converter

With PC connection

Supporting protocol for Data-Highway

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Degree of protection (IP)

IP20

With optical interface

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for other bus systems

4-quadrant operation possible

Supporting protocol for SUCONET

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

11kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Max. output at linear load at rated output voltage

11kW

Relative symmetric net voltage tolerance

10%

Max. output voltage

500V

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Nominal output current I2N

24A

Degree of protection (NEMA)

Other

Related products