Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height418.5mm
Number of digital inputs4
Width173mm
Power consumption607W
Depth211mm
With control elementYes
Number of analogue outputs1
Supporting protocol for PROFIBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
Supporting protocol for ModbusYes
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Number of analogue inputs2
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Number of HW-interfaces parallel0
Supporting protocol for DeviceNetNo
Supporting protocol for CANYes
Number of HW-interfaces USB0
Supporting protocol for LONNo
Supporting protocol for KNXNo
Number of HW-interfaces RS-4851
Number of digital outputs1
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4220
Supporting protocol for SERCOSNo
With PC connectionYes
Number of interfaces PROFINET0
Mains voltage380 - 480V
Max. output at linear load at rated output voltage15kW
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Type of converterU converter
Mains frequency50/60 Hz
Application in domestic- and commercial area permittedYes
Number of phases output3
Max. output frequency500Hz
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage15kW
Supporting protocol for PROFINET CBANo
4-quadrant operation possibleYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Integrated breaking resistanceYes
Number of phases input3
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for BACnetNo
Nominal output current I2N30A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34030NB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

418.5mm

Number of digital inputs

4

Width

173mm

Power consumption

607W

Depth

211mm

With control element

Number of analogue outputs

1

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

0

Supporting protocol for Modbus

Number of HW-interfaces industrial Ethernet

0

With optical interface

Number of analogue inputs

2

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet

Supporting protocol for CAN

Number of HW-interfaces USB

0

Supporting protocol for LON

Supporting protocol for KNX

Number of HW-interfaces RS-485

1

Number of digital outputs

1

Supporting protocol for SUCONET

Number of HW-interfaces RS-422

0

Supporting protocol for SERCOS

With PC connection

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Max. output at linear load at rated output voltage

15kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Mains frequency

50/60 Hz

Application in domestic- and commercial area permitted

Number of phases output

3

Max. output frequency

500Hz

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

15kW

Supporting protocol for PROFINET CBA

4-quadrant operation possible

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Integrated breaking resistance

Number of phases input

3

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for BACnet

Nominal output current I2N

30A

Related products