Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for PROFIBUSNo
Number of analogue outputs1
With control elementYes
Width173mm
Power consumption728W
Number of HW-interfaces RS-4220
Number of analogue inputs2
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of digital inputs4
Supporting protocol for ASINo
Number of digital outputs1
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for TCP/IPNo
Depth211mm
Height418.5mm
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Max. output at quadratic load at rated output voltage18.5kW
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Number of interfaces PROFINET0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Max. output frequency500Hz
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Mains voltage380 - 480V
Integrated breaking resistanceYes
Supporting protocol for other bus systemsYes
Type of converterU converter
4-quadrant operation possibleYes
Degree of protection (IP)IP20
With PC connectionYes
Number of phases output3
Number of phases input3
Max. output at linear load at rated output voltage18.5kW
Application in industrial area permittedYes
Mains frequency50/60 Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET IONo
Nominal output current I2N39A
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Max. output voltage500V
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34039FB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for PROFIBUS

Number of analogue outputs

1

With control element

Width

173mm

Power consumption

728W

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of digital inputs

4

Supporting protocol for ASI

Number of digital outputs

1

Number of HW-interfaces other

0

With optical interface

Supporting protocol for TCP/IP

Depth

211mm

Height

418.5mm

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Max. output at quadratic load at rated output voltage

18.5kW

Supporting protocol for Modbus

Supporting protocol for CAN

Number of interfaces PROFINET

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

Max. output frequency

500Hz

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Mains voltage

380 .. 480V

Integrated breaking resistance

Supporting protocol for other bus systems

Type of converter

U converter

4-quadrant operation possible

Degree of protection (IP)

IP20

With PC connection

Number of phases output

3

Number of phases input

3

Max. output at linear load at rated output voltage

18.5kW

Application in industrial area permitted

Mains frequency

50/60 Hz

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET IO

Nominal output current I2N

39A

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Max. output voltage

500V

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.