Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height418.5mm
Power consumption728W
With control elementYes
Number of digital inputs4
Depth211mm
Width173mm
Number of digital outputs1
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Number of analogue outputs1
Number of analogue inputs2
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet0
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Supporting protocol for ModbusYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
With PC connectionYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Max. output at linear load at rated output voltage18.5kW
Number of phases output3
Supporting protocol for Data-HighwayNo
Number of phases input3
Max. output frequency500Hz
Supporting protocol for SERCOSNo
Mains voltage380 - 480V
Degree of protection (IP)IP20
Max. output at quadratic load at rated output voltage18.5kW
Supporting protocol for CANYes
Supporting protocol for other bus systemsYes
Type of converterU converter
Supporting protocol for DeviceNetNo
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N39A
Degree of protection (NEMA)Other
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34039NB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

418.5mm

Power consumption

728W

With control element

Number of digital inputs

4

Depth

211mm

Width

173mm

Number of digital outputs

1

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Number of analogue outputs

1

Number of analogue inputs

2

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

With PC connection

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Integrated breaking resistance

Number of interfaces PROFINET

0

Max. output at linear load at rated output voltage

18.5kW

Number of phases output

3

Supporting protocol for Data-Highway

Number of phases input

3

Max. output frequency

500Hz

Supporting protocol for SERCOS

Mains voltage

380 .. 480V

Degree of protection (IP)

IP20

Max. output at quadratic load at rated output voltage

18.5kW

Supporting protocol for CAN

Supporting protocol for other bus systems

Type of converter

U converter

Supporting protocol for DeviceNet

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Nominal output current I2N

39A

Degree of protection (NEMA)

Other

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Related products