Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Depth211mm
Height418.5mm
With control elementYes
Power consumption801W
Number of digital inputs4
Width173mm
Number of digital outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces parallel0
Supporting protocol for CANYes
Number of HW-interfaces RS-4220
Supporting protocol for Data-HighwayNo
With PC connectionYes
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Degree of protection (IP)IP20
Number of HW-interfaces other0
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-2320
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusYes
Number of analogue outputs1
Supporting protocol for SERCOSNo
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Max. output frequency500Hz
Supporting protocol for PROFINET CBANo
Mains voltage380 - 480V
Number of phases input3
Max. output at linear load at rated output voltage22kW
Mains frequency50/60 Hz
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
4-quadrant operation possibleYes
Number of phases output3
Max. output at quadratic load at rated output voltage22kW
Supporting protocol for PROFINET IONo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Nominal output current I2N46A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-34046NB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Depth

211mm

Height

418.5mm

With control element

Power consumption

801W

Number of digital inputs

4

Width

173mm

Number of digital outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Number of HW-interfaces RS-422

0

Supporting protocol for Data-Highway

With PC connection

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for KNX

Degree of protection (IP)

IP20

Number of HW-interfaces other

0

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-232

0

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Number of analogue outputs

1

Supporting protocol for SERCOS

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Max. output frequency

500Hz

Supporting protocol for PROFINET CBA

Mains voltage

380 .. 480V

Number of phases input

3

Max. output at linear load at rated output voltage

22kW

Mains frequency

50/60 Hz

Application in industrial area permitted

Application in domestic- and commercial area permitted

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Max. output voltage

500V

4-quadrant operation possible

Number of phases output

3

Max. output at quadratic load at rated output voltage

22kW

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS-Safety

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Nominal output current I2N

46A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.