Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height184mm
Width81mm
Power consumption63.75W
Depth124mm
Number of digital inputs4
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
Number of digital outputs1
Number of HW-interfaces RS-2320
With control elementYes
Supporting protocol for LONNo
Number of analogue inputs2
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Mains voltage380 - 480V
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for DeviceNetNo
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Type of converterU converter
Max. output at quadratic load at rated output voltage0.75kW
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
Number of phases output3
Supporting protocol for AS-Interface Safety at WorkNo
Number of interfaces PROFINET0
Max. output at linear load at rated output voltage0.75kW
Number of phases input3
Integrated breaking resistanceNo
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Max. output voltage500V
Nominal output current I2N2.2A
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-342D2FN-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

184mm

Width

81mm

Power consumption

63.75W

Depth

124mm

Number of digital inputs

4

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

Number of digital outputs

1

Number of HW-interfaces RS-232

0

With control element

Supporting protocol for LON

Number of analogue inputs

2

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Mains voltage

380 .. 480V

Supporting protocol for SUCONET

With PC connection

Supporting protocol for DeviceNet

4-quadrant operation possible

Mains frequency

50/60 Hz

Type of converter

U converter

Max. output at quadratic load at rated output voltage

0.75kW

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

Number of phases output

3

Supporting protocol for AS-Interface Safety at Work

Number of interfaces PROFINET

0

Max. output at linear load at rated output voltage

0.75kW

Number of phases input

3

Integrated breaking resistance

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Max. output voltage

500V

Nominal output current I2N

2.2A

Supporting protocol for PROFINET IO

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.