Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width81mm
Number of HW-interfaces industrial Ethernet0
Depth124mm
Supporting protocol for ModbusYes
With control elementYes
Number of digital inputs4
Number of analogue outputs1
Supporting protocol for LONNo
Height184mm
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces RS-2320
Supporting protocol for PROFIBUSNo
Power consumption76.5W
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPNo
Number of analogue inputs2
Supporting protocol for KNXNo
Supporting protocol for CANYes
Number of HW-interfaces other0
Number of digital outputs1
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Degree of protection (IP)IP20
Supporting protocol for Data-HighwayNo
4-quadrant operation possibleNo
Supporting protocol for SUCONETNo
Max. output frequency500Hz
Number of interfaces PROFINET0
Application in industrial area permittedYes
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Mains voltage380 - 480V
Relative symmetric net voltage tolerance10%
Type of converterU converter
Number of phases input3
With PC connectionYes
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Number of phases output3
Supporting protocol for SERCOSNo
Max. output at quadratic load at rated output voltage1.5kW
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Max. output voltage500V
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N4.1A
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-344D1NN-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

81mm

Number of HW-interfaces industrial Ethernet

0

Depth

124mm

Supporting protocol for Modbus

With control element

Number of digital inputs

4

Number of analogue outputs

1

Supporting protocol for LON

Height

184mm

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces RS-232

0

Supporting protocol for PROFIBUS

Power consumption

76.5W

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Number of analogue inputs

2

Supporting protocol for KNX

Supporting protocol for CAN

Number of HW-interfaces other

0

Number of digital outputs

1

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Degree of protection (IP)

IP20

Supporting protocol for Data-Highway

4-quadrant operation possible

Supporting protocol for SUCONET

Max. output frequency

500Hz

Number of interfaces PROFINET

0

Application in industrial area permitted

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Mains voltage

380 .. 480V

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Number of phases input

3

With PC connection

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Number of phases output

3

Supporting protocol for SERCOS

Max. output at quadratic load at rated output voltage

1.5kW

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Max. output voltage

500V

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

4.1A

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.