Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue outputs1
Depth152mm
Number of analogue inputs2
Height231mm
Width107mm
Number of digital outputs1
Power consumption44W
Number of digital inputs4
With control elementYes
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for SUCONETNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for CANYes
Number of phases output1
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Degree of protection (IP)IP20
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Type of converterU converter
Supporting protocol for other bus systemsYes
With PC connectionYes
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output at linear load at rated output voltage1.1kW
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Max. output frequency500Hz
Relative symmetric net voltage tolerance10%
Max. output voltage250V
Number of phases input1
Supporting protocol for PROFINET IONo
Application in industrial area permittedYes
Integrated breaking resistanceYes
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N11A
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DC1-S2011FB-A20CE1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue outputs

1

Depth

152mm

Number of analogue inputs

2

Height

231mm

Width

107mm

Number of digital outputs

1

Power consumption

44W

Number of digital inputs

4

With control element

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

With optical interface

Supporting protocol for SUCONET

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for CAN

Number of phases output

1

4-quadrant operation possible

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Type of converter

U converter

Supporting protocol for other bus systems

With PC connection

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output at linear load at rated output voltage

1.1kW

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Max. output frequency

500Hz

Relative symmetric net voltage tolerance

10%

Max. output voltage

250V

Number of phases input

1

Supporting protocol for PROFINET IO

Application in industrial area permitted

Integrated breaking resistance

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

11A

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.