Details

  • Relays
  • Device for monitoring of safety-related circuits
  • 1 KOM
  • EATON

Technical specifications

ModelBasic device
Control voltage 124 - 230V
Release-delay0 - 0s
Control voltage 224 - 230V
Depth114.5mm
Height113mm
Type of control voltage 1AC/DC
With approval according to ULYes
Power consumption2.9W
With feedback circuitYes
Number of outputs, safety related, undelayed, semiconductors0
With muting functionNo
Number of outputs, signalling function, undelayed, semiconductors0
Type of control voltage 2AC/DC
Number of outputs, safety related, delayed, with contact0
With start inputYes
Type of electric connectionScrew connection
Suitable for monitoring of proximity switchesNo
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
With approval for BG BIANo
Suitable for monitoring of magnetic switchesYes
Suitable for monitoring of position switchesNo
Number of outputs, signalling function, delayed, with contact0
With detachable clampsYes
Rated switch current5A
Suitable for monitoring of optoelectronic protection equipmentYes
Voltage type (operating voltage)AC/DC
Suitable for monitoring of emergency-stop circuitsYes
Suitable for monitoring of valvesNo
Operating voltage at AC 60 Hz24 - 230V
SIL according to IEC 615083
Operating voltage at AC 50 Hz24 - 230V
With approval for TÜVNo
Supply voltage AC 60 Hz24 - 230V
Evaluation inputsOne- and two-channel
Suitable for monitoring of tactile sensorsNo
Stop category according to IEC 602040
Operating voltage at DC24 - 230V
Rail mounting possibleYes
Number of outputs, safety related, undelayed, with contact3
Number of outputs, signalling function, undelayed, with contact1
Width22.5mm
Voltage type of supply voltageAC/DC
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
Supply voltage AC 50 Hz24 - 230V
Supply voltage DC24 - 230V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user