Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Width60.8mm
Input current at signal 14mA
Depth34mm
Height156.8mm
Suitable for safety functionsNo
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Type of voltage (input voltage)DC
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for ASINo
Number of HW-interfaces RS-4850
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Time delay at signal exchange0.2 - 0.2ms
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Output current0.5A
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Short-circuit protection, outputs availableYes
Type of electric connectionScrew connection
Type of digital outputOther
Explosion safety category for gasNone
Explosion safety category for dustNone
Rail mounting possibleNo
System accessoryYes
Fieldbus connection over separate bus coupler possibleYes
IO link masterNo
Appendant operation agent (Ex ia)No
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPNo
Number of HW-interfaces Wireless0
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Appendant operation agent (Ex ib)No
Supporting protocol for DeviceNet SafetyNo
Rack-assembly possibleNo
Front built-in possibleNo
Radio standard Wi-Fi 802.11No
Wall mounting/direct mountingYes
Supporting protocol for PROFINET CBANo
Supply voltage AC 60 Hz0 - 0V
Permitted voltage at input20.4 - 28.8V
Digital inputs configurableNo
Supporting protocol for Foundation FieldbusNo
Supply voltage DC20.4 - 28.8V
Supporting protocol for PROFIsafeNo
Digital outputs configurableNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Permitted voltage at output20.4 - 28.8V
Type of output voltageDC
Supply voltage AC 50 Hz0 - 0V
Radio standard UMTSNo
SIL according to IEC 61508None
Supporting protocol for EtherCATNo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IIINo
Radio standard GPRSNo
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location division 2No
Radio standard GSMNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Number of digital inputs4
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP69K

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user