Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Height156.8mm
Width60.8mm
Input current at signal 14mA
Suitable for safety functionsNo
Depth34mm
Time delay at signal exchange0.2 - 0.2ms
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Supporting protocol for CANNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4850
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Type of voltage (input voltage)DC
With optical interfaceNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Short-circuit protection, outputs availableYes
Appendant operation agent (Ex ib)No
Type of electric connectionScrew connection
Number of HW-interfaces Wireless0
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Appendant operation agent (Ex ia)No
Type of digital outputOther
System accessoryYes
Explosion safety category for gasNone
Explosion safety category for dustNone
Number of interfaces PROFINET0
Output current0.5A
Fieldbus connection over separate bus coupler possibleYes
Supporting protocol for other bus systemsYes
Rail mounting possibleNo
IO link masterNo
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Performance level according to EN ISO 13849-1None
Wall mounting/direct mountingYes
Front built-in possibleNo
Rack-assembly possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supply voltage DC20.4 - 28.8V
Digital outputs configurableYes
Permitted voltage at output20.4 - 28.8V
Type of output voltageDC
Supporting protocol for PROFINET IONo
Radio standard GSMNo
Radio standard GPRSNo
Digital inputs configurableYes
Supply voltage AC 60 Hz0 - 0V
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Permitted voltage at input20.4 - 28.8V
Supporting protocol for PROFIsafeNo
Radio standard UMTSNo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location class INo
Certified for UL hazardous location division 2No
Supporting protocol for EtherCATNo
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 1No
SIL according to IEC 61508None
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group E (metal dusts)No
Number of digital inputs8
Number of digital outputs8
Voltage type of supply voltageDC
Degree of protection (IP)IP69K

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user