Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU6E-SWD-8DD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Height
156.8mm
Width
60.8mm
Input current at signal 1
4mA
Suitable for safety functions
Depth
34mm
Number of digital inputs
8
Number of digital outputs
8
Time delay at signal exchange
0.2 .. 0.2ms
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
0
Voltage type of supply voltage
DC
Supporting protocol for CAN
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for INTERBUS
Number of HW-interfaces serial TTY
0
Number of HW-interfaces other
0
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Number of HW-interfaces parallel
0
Type of voltage (input voltage)
DC
With optical interface
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Short-circuit protection, outputs available
Appendant operation agent (Ex ib)
Type of electric connection
Screw connection
Number of HW-interfaces Wireless
0
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Appendant operation agent (Ex ia)
Type of digital output
Other
System accessory
Explosion safety category for gas
None
Explosion safety category for dust
None
Degree of protection (IP)
IP69K
Number of interfaces PROFINET
0
Output current
0.5A
Fieldbus connection over separate bus coupler possible
Supporting protocol for other bus systems
Rail mounting possible
IO link master
Radio standard Wi-Fi 802.11
Radio standard Bluetooth
Performance level according to EN ISO 13849-1
None
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supply voltage DC
20.4 .. 28.8V
Digital outputs configurable
Permitted voltage at output
20.4 .. 28.8V
Type of output voltage
DC
Supporting protocol for PROFINET IO
Radio standard GSM
Radio standard GPRS
Digital inputs configurable
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Permitted voltage at input
20.4 .. 28.8V
Supporting protocol for PROFIsafe
Radio standard UMTS
Certified for UL hazardous location class III
Certified for UL hazardous location class I
Certified for UL hazardous location division 2
Supporting protocol for EtherCAT
Certified for UL hazardous location class II
Certified for UL hazardous location division 1
SIL according to IEC 61508
None
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group E (metal dusts)