Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Time delay at signal exchange0.2 - 0.2ms
Suitable for safety functionsNo
Height156.8mm
Depth34mm
Input current at signal 10mA
Width60.8mm
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Supporting protocol for KNXNo
Type of digital outputOther
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Output current0.5A
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
With optical interfaceNo
Supporting protocol for SUCONETNo
Type of voltage (input voltage)DC
Supporting protocol for CANNo
Type of electric connectionScrew connection
Supporting protocol for other bus systemsYes
Short-circuit protection, outputs availableYes
Appendant operation agent (Ex ia)No
Explosion safety category for dustNone
System accessoryYes
Explosion safety category for gasNone
Rail mounting possibleNo
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ib)No
Rack-assembly possibleNo
Number of interfaces PROFINET0
Front built-in possibleNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Number of HW-interfaces Wireless0
Wall mounting/direct mountingYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
IO link masterNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFIsafeNo
Performance level according to EN ISO 13849-1None
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supply voltage AC 60 Hz0 - 0V
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supply voltage DC20.4 - 28.8V
Permitted voltage at output20.4 - 28.8V
Digital inputs configurableNo
Permitted voltage at input20.4 - 28.8V
Type of output voltageDC
Radio standard GPRSNo
Digital outputs configurableNo
Radio standard GSMNo
Certified for UL hazardous location class INo
Radio standard UMTSNo
Certified for UL hazardous location class IINo
SIL according to IEC 61508None
Supporting protocol for EtherCATNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location class IIINo
Number of digital inputs0
Number of digital outputs8
Voltage type of supply voltageDC
Degree of protection (IP)IP69K