Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU8E-SWD-16DD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Height
212.6mm
Width
61.6mm
Depth
34mm
Time delay at signal exchange
0.2 .. 0.2ms
Number of digital outputs
16
Number of digital inputs
16
Input current at signal 1
4mA
Suitable for safety functions
Number of HW-interfaces RS-485
0
With optical interface
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces RS-232
0
Supporting protocol for LON
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for TCP/IP
Type of voltage (input voltage)
DC
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for CAN
Output current
0.5A
Voltage type of supply voltage
DC
Short-circuit protection, outputs available
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Type of digital output
Other
Rail mounting possible
Explosion safety category for gas
None
Type of electric connection
Screw connection
Supporting protocol for INTERBUS-Safety
System accessory
Supporting protocol for SERCOS
Fieldbus connection over separate bus coupler possible
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Degree of protection (IP)
IP69K
Number of HW-interfaces Wireless
0
Rack-assembly possible
Number of interfaces PROFINET
0
Wall mounting/direct mounting
Supporting protocol for EtherNet/IP
Front built-in possible
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
IO link master
Performance level according to EN ISO 13849-1
None
Radio standard Wi-Fi 802.11
Radio standard Bluetooth
Explosion safety category for dust
None
Permitted voltage at input
20.4 .. 28.8V
Digital inputs configurable
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Type of output voltage
DC
Supply voltage DC
20.4 .. 28.8V
Permitted voltage at output
20.4 .. 28.8V
Supporting protocol for PROFINET CBA
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for SafetyBUS p
Supporting protocol for EtherCAT
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Digital outputs configurable
Radio standard UMTS
Certified for UL hazardous location division 1
SIL according to IEC 61508
None
Certified for UL hazardous location class I
Radio standard GPRS
Certified for UL hazardous location division 2
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Supply voltage AC 60 Hz
0 .. 0V
Radio standard GSM
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group D (propane)