Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • EATON

Technical specifications

Height212.6mm
Width61.6mm
Depth34mm
Time delay at signal exchange0.2 - 0.2ms
Input current at signal 14mA
Suitable for safety functionsNo
Number of HW-interfaces RS-4850
With optical interfaceNo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Type of voltage (input voltage)DC
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Output current0.5A
Short-circuit protection, outputs availableYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Type of digital outputOther
Rail mounting possibleNo
Explosion safety category for gasNone
Type of electric connectionScrew connection
Supporting protocol for INTERBUS-SafetyNo
System accessoryYes
Supporting protocol for SERCOSNo
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ia)No
Appendant operation agent (Ex ib)No
Number of HW-interfaces Wireless0
Rack-assembly possibleNo
Number of interfaces PROFINET0
Wall mounting/direct mountingYes
Supporting protocol for EtherNet/IPNo
Front built-in possibleNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
IO link masterNo
Performance level according to EN ISO 13849-1None
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Explosion safety category for dustNone
Permitted voltage at input20.4 - 28.8V
Digital inputs configurableYes
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Type of output voltageDC
Supply voltage DC20.4 - 28.8V
Permitted voltage at output20.4 - 28.8V
Supporting protocol for PROFINET CBANo
Supply voltage AC 50 Hz0 - 0V
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherCATNo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Digital outputs configurableYes
Radio standard UMTSNo
Certified for UL hazardous location division 1No
SIL according to IEC 61508None
Certified for UL hazardous location class INo
Radio standard GPRSNo
Certified for UL hazardous location division 2No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)No
Supply voltage AC 60 Hz0 - 0V
Radio standard GSMNo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Number of digital inputs16
Number of digital outputs16
Voltage type of supply voltageDC
Degree of protection (IP)IP69K