Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP31
Number of poles4
Type of control elementPush button
Rated permanent current Iu1600A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Overload release current setting800 - 1600A
Rated voltage690 - 690V
Type of electrical connection of main circuitRail connection
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact2
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release3200 - 19200A
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release3200 - 16000A
Position of connection for main current circuitBack side
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Complete device with protection unitYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

IZMX16B4-P16F-1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP31

Number of poles

4

Type of control element

Push button

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Overload release current setting

800 .. 1600A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Rail connection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

2

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

3200 .. 19200A

With under voltage release

Adjustment range short-term delayed short-circuit release

3200 .. 16000A

Position of connection for main current circuit

Back side

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Complete device with protection unit

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Related products