Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP31
Type of control elementPush button
Number of poles3
Rated permanent current Iu1600A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Overload release current setting800 - 1600A
Device constructionBuilt-in device slide-in technique (withdrawable)
Motor drive optionalYes
Type of electrical connection of main circuitRail connection
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact2
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release3200 - 19200A
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Adjustment range short-term delayed short-circuit release3200 - 16000A
Position of connection for main current circuitBack side
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Complete device with protection unitYes
Integrated earth fault protectionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

IZMX40B3-P16W-1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP31

Type of control element

Push button

Number of poles

3

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Overload release current setting

800 .. 1600A

Device construction

Built-in device slide-in technique (withdrawable)

Motor drive optional

Type of electrical connection of main circuit

Rail connection

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

2

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

3200 .. 19200A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Adjustment range short-term delayed short-circuit release

3200 .. 16000A

Position of connection for main current circuit

Back side

DIN rail (top hat rail) mounting optional

With under voltage release

Complete device with protection unit

Integrated earth fault protection

Related products