Technical specifications

Degree of protection (IP)IP31
Type of control elementPush button
Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1250A
Number of auxiliary contacts as normally open contact0
Overload release current setting625 - 1250A
Motor drive integratedNo
Type of electrical connection of main circuitRail connection
Motor drive optionalYes
Number of auxiliary contacts as change-over contact2
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release2500 - 15000A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz105kA
Adjustment range short-term delayed short-circuit release2500 - 12500A
Position of connection for main current circuitBack side
Complete device with protection unitYes
Integrated earth fault protectionNo
With switched-off indicatorYes
With under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

IZMX40H3-P12W-1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP31

Type of control element

Push button

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1250A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

625 .. 1250A

Motor drive integrated

Type of electrical connection of main circuit

Rail connection

Motor drive optional

Number of auxiliary contacts as change-over contact

2

Device construction

Built-in device slide-in technique (withdrawable)

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

2500 .. 15000A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

105kA

Adjustment range short-term delayed short-circuit release

2500 .. 12500A

Position of connection for main current circuit

Back side

Complete device with protection unit

Integrated earth fault protection