Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP31
Type of control elementPush button
Number of poles3
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu800A
Overload release current setting400 - 800A
Type of electrical connection of main circuitRail connection
Number of auxiliary contacts as change-over contact2
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1600 - 9600A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz105kA
Adjustment range short-term delayed short-circuit release1600 - 8000A
Position of connection for main current circuitBack side
Complete device with protection unitYes
Integrated earth fault protectionNo
With switched-off indicatorYes
With under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

IZMX40H3-V08F-1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP31

Type of control element

Push button

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

800A

Overload release current setting

400 .. 800A

Type of electrical connection of main circuit

Rail connection

Number of auxiliary contacts as change-over contact

2

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1600 .. 9600A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

105kA

Adjustment range short-term delayed short-circuit release

1600 .. 8000A

Position of connection for main current circuit

Back side

Complete device with protection unit

Integrated earth fault protection

With switched-off indicator

With under voltage release

Related products