Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP31
Number of poles3
Type of control elementPush button
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu2000A
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Overload release current setting1000 - 2000A
Rated voltage690 - 690V
Type of electrical connection of main circuitRail connection
Number of auxiliary contacts as change-over contact2
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release4000 - 24000A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release4000 - 20000A
Position of connection for main current circuitBack side
Complete device with protection unitYes
With switched-off indicatorYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

IZMX40N3-P20F-1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP31

Number of poles

3

Type of control element

Push button

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

2000A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Overload release current setting

1000 .. 2000A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Rail connection

Number of auxiliary contacts as change-over contact

2

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

4000 .. 24000A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Adjustment range short-term delayed short-circuit release

4000 .. 20000A

Position of connection for main current circuit

Back side

Complete device with protection unit

With switched-off indicator

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA