Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Rated operation power at AC-3, 400 V0.06kW
With transformerNo
Suitable for emergency stopNo
Power consumption2.6W
Height180mm
Number of auxiliary contacts as normally open contact1
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Supporting protocol for ASINo
Overload release current setting0.16 - 0.25A
Number of auxiliary contacts as normally closed contact0
Number of command positions0
Depth115mm
Number of indicator lights0
Rated operation current Ie0.21A
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNetNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for other bus systemsNo
Degree of protection (IP)IP20
With short-circuit releaseYes
With fuseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Release classCLASS 10 A
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for Data-HighwayNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
External reset possibleNo
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase0.04kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V0.25A
Rated power, 460 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-0,25-M7(24VDC)/MSFA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Rated operation power at AC-3, 400 V

0.06kW

With transformer

Suitable for emergency stop

Power consumption

2.6W

Height

180mm

Number of auxiliary contacts as normally open contact

1

Supporting protocol for PROFIBUS

Supporting protocol for LON

Supporting protocol for ASI

Overload release current setting

0.16 .. 0.25A

Number of auxiliary contacts as normally closed contact

0

Number of command positions

0

Depth

115mm

Number of indicator lights

0

Rated operation current Ie

0.21A

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for DeviceNet

Rail mounting possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for other bus systems

Degree of protection (IP)

IP20

With short-circuit release

With fuse

Type of electrical connection of main circuit

Screw connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SUCONET

Release class

CLASS 10 A

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for Data-Highway

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

External reset possible

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

0.25A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.