Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Depth115mm
Height180mm
Width45mm
Number of indicator lights0
With transformerNo
Suitable for emergency stopNo
Supporting protocol for ASINo
Number of command positions0
Number of auxiliary contacts as normally open contact1
Power consumption2.6W
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Release classCLASS 10 A
Supporting protocol for Foundation FieldbusNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
External reset possibleNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for other bus systemsNo
Rail mounting possibleNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated power, 460 V, 60 Hz, 3-phase0kW
Degree of protection (NEMA)Other
Rated operation power at AC-3, 230 V, 3-phase0.25kW
Ambient temperature, upper operating limit55°C
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for PROFINET IONo
Rated operation power at AC-3, 400 V0.55kW
Rated operation current Ie1.5A
Overload release current setting1 - 1.6A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V1.6A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user