Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase4kW
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated control supply voltage Us at AC 60HZ0 - 0V
Overload release current setting10 - 16A
Rated operation current at AC-3, 400 V15A
Rated power, 575 V, 60 Hz, 3-phase0kW
Number of auxiliary contacts as normally open contact1
Rated operation power at AC-3, 400 V7.5kW
Rated conditional short-circuit current, type 2, 400 V50A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Ambient temperature, upper operating limit55°C
Power consumption2.6W
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Number of command positions0
Release classCLASS 10 A
Coordination class according to IEC 60947-4-3Class 1
Number of indicator lights0
Rated operation current Ie15.2A
Rated conditional short-circuit current, type 2, 230 V0A
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
With transformerNo
Degree of protection (IP)IP20
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Temperature compensated overload protectionYes
Rail mounting possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET IONo
External reset possibleNo
Suitable for emergency stopNo
Supporting protocol for PROFINET CBANo
Supporting protocol for ASINo
With fuseNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for LONNo
Degree of protection (NEMA)Other
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Height180mm
Width45mm
Supporting protocol for other bus systemsNo
Depth115mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-16-M15(24VDC)/MSFA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

4kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Overload release current setting

10 .. 16A

Rated operation current at AC-3, 400 V

15A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Number of auxiliary contacts as normally open contact

1

Rated operation power at AC-3, 400 V

7.5kW

Rated conditional short-circuit current, type 2, 400 V

50A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Ambient temperature, upper operating limit

55°C

Power consumption

2.6W

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Number of command positions

0

Release class

CLASS 10 A

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 2, 230 V

0A

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

With transformer

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for Modbus

Temperature compensated overload protection

Rail mounting possible

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

External reset possible

Suitable for emergency stop

Supporting protocol for PROFINET CBA

Supporting protocol for ASI

With fuse

Supporting protocol for Foundation Fieldbus

Supporting protocol for LON

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Height

180mm

Width

45mm

Supporting protocol for other bus systems

Depth

115mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.