Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-1-M7(24VDC)/MSFA

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Height
180mm
Rated operation power at AC-3, 400 V
0.25kW
With transformer
Depth
115mm
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
0.8A
Number of command positions
0
Number of indicator lights
0
Overload release current setting
0.63 .. 1A
Supporting protocol for CAN
Suitable for emergency stop
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Power consumption
2.6W
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
External reset possible
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Rail mounting possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Supporting protocol for DeviceNet Safety
Type of motor starter
Direct online starter (DOL)
Supporting protocol for Foundation Fieldbus
With fuse
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SERCOS
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Rated power, 460 V, 60 Hz, 3-phase
0kW
With short-circuit release
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
1A
Supporting protocol for INTERBUS-Safety
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for EtherNet/IP
Ambient temperature, upper operating limit
55°C
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A