Aleta.hr
Main Product Image

MSC-DM-2,5-M7(24VDC)/MSFA

Code: 1746816

ManufacturerRAZNO
Catalog number191107
Type
EAN code4015081916054

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated control supply voltage Us at DC

24 - 24V

Voltage type for actuating

DC

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation power at AC-3, 400 V

0.75kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

1.6 - 2.5A

Power consumption

2.6W

Rated operation current Ie

1.9A

Rated operation current at AC-3, 400 V

2.5A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 400 V

50000A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

With short-circuit release

Yes

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Yes

Rated control supply voltage Us at AC 50HZ

0 - 0V

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

180mm

Depth

115mm

Rail mounting possible

No

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of command positions

0

With transformer

No

Suitable for emergency stop

No

Number of indicator lights

0

External reset possible

No

With fuse

No

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for CAN

No

Supporting protocol for TCP/IP

No

Supporting protocol for INTERBUS

No

Supporting protocol for PROFIBUS

No

Supporting protocol for ASI

No

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-2,5-M7(24VDC)/MSFA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated control supply voltage Us at DC

24 .. 24V

Voltage type for actuating

DC

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 400 V

0.75kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

1.6 .. 2.5A

Power consumption

2.6W

Rated operation current Ie

1.9A

Rated operation current at AC-3, 400 V

2.5A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 400 V

50000A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

With short-circuit release

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

180mm

Depth

115mm

Rail mounting possible

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of command positions

0

With transformer

Suitable for emergency stop

Number of indicator lights

0

External reset possible

With fuse

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.