Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for ModbusNo
Suitable for emergency stopNo
Supporting protocol for CANNo
Rated operation current Ie1.9A
Power consumption2.6W
Supporting protocol for ASINo
Number of indicator lights0
Number of auxiliary contacts as normally closed contact0
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Depth115mm
Height180mm
Overload release current setting1.6 - 2.5A
With transformerNo
Number of command positions0
Supporting protocol for TCP/IPNo
External reset possibleNo
Supporting protocol for Data-HighwayNo
Number of auxiliary contacts as normally open contact1
Supporting protocol for SUCONETNo
Rated operation power at AC-3, 400 V0.75kW
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUSNo
Width45mm
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Degree of protection (IP)IP20
Type of motor starterDirect online starter (DOL)
With short-circuit releaseYes
Supporting protocol for PROFINET CBANo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SERCOSNo
Rail mounting possibleNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Voltage type for actuatingDC
Supporting protocol for EtherNet/IPNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Rated power, 460 V, 60 Hz, 3-phase0kW
With fuseNo
Rated operation current at AC-3, 400 V2.5A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-2,5-M7(24VDC)/MSFA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for Modbus

Suitable for emergency stop

Supporting protocol for CAN

Rated operation current Ie

1.9A

Power consumption

2.6W

Supporting protocol for ASI

Number of indicator lights

0

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for LON

Supporting protocol for PROFIBUS

Depth

115mm

Height

180mm

Overload release current setting

1.6 .. 2.5A

With transformer

Number of command positions

0

Supporting protocol for TCP/IP

External reset possible

Supporting protocol for Data-Highway

Number of auxiliary contacts as normally open contact

1

Supporting protocol for SUCONET

Rated operation power at AC-3, 400 V

0.75kW

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Width

45mm

Supporting protocol for DeviceNet

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Degree of protection (IP)

IP20

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Supporting protocol for PROFINET CBA

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for SERCOS

Rail mounting possible

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Voltage type for actuating

DC

Supporting protocol for EtherNet/IP

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Rated power, 460 V, 60 Hz, 3-phase

0kW

With fuse

Rated operation current at AC-3, 400 V

2.5A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A