

Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-2,5-M7(24VDC)/MSFA

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Supporting protocol for Modbus
Suitable for emergency stop
Supporting protocol for CAN
Rated operation current Ie
1.9A
Power consumption
2.6W
Supporting protocol for ASI
Number of indicator lights
0
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for LON
Supporting protocol for PROFIBUS
Depth
115mm
Height
180mm
Overload release current setting
1.6 .. 2.5A
With transformer
Number of command positions
0
Supporting protocol for TCP/IP
External reset possible
Supporting protocol for Data-Highway
Number of auxiliary contacts as normally open contact
1
Supporting protocol for SUCONET
Rated operation power at AC-3, 400 V
0.75kW
Supporting protocol for other bus systems
Supporting protocol for INTERBUS
Width
45mm
Supporting protocol for DeviceNet
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Degree of protection (IP)
IP20
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Supporting protocol for PROFINET CBA
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for SERCOS
Rail mounting possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Voltage type for actuating
DC
Supporting protocol for EtherNet/IP
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Rated power, 460 V, 60 Hz, 3-phase
0kW
With fuse
Rated operation current at AC-3, 400 V
2.5A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A