Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-4-M7(24VDC)/MSFA

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Power consumption
2.6W
Depth
115mm
Suitable for emergency stop
Supporting protocol for INTERBUS
With transformer
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
2.5 .. 4A
Supporting protocol for DeviceNet
Number of command positions
0
Rated operation current Ie
3.6A
Supporting protocol for LON
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Number of auxiliary contacts as normally open contact
1
Rated operation power at AC-3, 400 V
1.5kW
Supporting protocol for CAN
Height
180mm
Supporting protocol for SUCONET
Number of indicator lights
0
Rail mounting possible
Supporting protocol for other bus systems
External reset possible
Type of electrical connection of main circuit
Screw connection
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Type of motor starter
Direct online starter (DOL)
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Rated power, 575 V, 60 Hz, 3-phase
0kW
Release class
CLASS 10 A
Supporting protocol for INTERBUS-Safety
Rated power, 460 V, 60 Hz, 3-phase
0kW
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With fuse
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Rated operation current at AC-3, 400 V
4A
Supporting protocol for SafetyBUS p
Voltage type for actuating
DC
Supporting protocol for PROFINET IO
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With short-circuit release
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 230 V
50000A