Aleta.hr
Main Product Image

MSC-DM-6,3-M7(230V50HZ)/MSFA

Code: 1746819

ManufacturerRAZNO
Catalog number191121
Type
EAN code4015081916191

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Yes

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated control supply voltage Us at DC

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated operation power at AC-3, 400 V

2.2kW

Type of motor starter

Direct online starter (DOL)

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated control supply voltage Us at AC 60HZ

0 - 0V

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

6.3A

Rated conditional short-circuit current, type 2, 400 V

50000A

Overload release current setting

4 - 6.3A

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of auxiliary contacts as normally open contact

1

With transformer

No

Number of indicator lights

0

Supporting protocol for PROFIBUS

No

Temperature compensated overload protection

Yes

Supporting protocol for TCP/IP

No

Rail mounting possible

Yes

Suitable for emergency stop

No

Supporting protocol for CAN

No

Number of command positions

0

External reset possible

No

Supporting protocol for ASI

No

Release class

CLASS 10 A

With fuse

No

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

5A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (IP)

IP20

Supporting protocol for Data-Highway

No

Degree of protection (NEMA)

Other

Supporting protocol for Modbus

No

Supporting protocol for INTERBUS

No

Supporting protocol for SUCONET

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFINET IO

No

Supporting protocol for DeviceNet

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for PROFIsafe

No

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for other bus systems

No

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-6,3-M7(230V50HZ)/MSFA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at DC

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated operation power at AC-3, 400 V

2.2kW

Type of motor starter

Direct online starter (DOL)

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

6.3A

Rated conditional short-circuit current, type 2, 400 V

50000A

Overload release current setting

4 .. 6.3A

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of auxiliary contacts as normally open contact

1

With transformer

Number of indicator lights

0

Supporting protocol for PROFIBUS

Temperature compensated overload protection

Supporting protocol for TCP/IP

Rail mounting possible

Suitable for emergency stop

Supporting protocol for CAN

Number of command positions

0

External reset possible

Supporting protocol for ASI

Release class

CLASS 10 A

With fuse

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

5A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (IP)

IP20

Supporting protocol for Data-Highway

Degree of protection (NEMA)

Other

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for other bus systems

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.