Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-6,3-M7(24VDC)/MSFA

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Height
180mm
Width
45mm
Depth
115mm
With transformer
Power consumption
2.6W
Rated operation power at AC-3, 400 V
2.2kW
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Number of indicator lights
0
Supporting protocol for LON
Overload release current setting
4 .. 6.3A
Suitable for emergency stop
Rated operation current Ie
5A
Number of command positions
0
Supporting protocol for DeviceNet
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for other bus systems
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
External reset possible
With short-circuit release
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Release class
CLASS 10 A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for INTERBUS-Safety
With fuse
Degree of protection (IP)
IP20
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for PROFIsafe
Rated operation current at AC-3, 400 V
6.3A
Temperature compensated overload protection
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for SafetyBUS p
Supporting protocol for EtherNet/IP
Type of motor starter
Direct online starter (DOL)
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 400 V
50000A
Degree of protection (NEMA)
Other
Ambient temperature, upper operating limit
55°C
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for PROFINET IO
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A