Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu160A
Overload release current setting0 - 0A
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release2500 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Number of poles3
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Complete device with protection unitYes
Number of auxiliary contacts as normally open contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NS2-160-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

160A

Overload release current setting

0 .. 0A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

2500 .. 2500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Number of poles

3

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

Related products