Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting70 - 70A
Rated voltage440 - 440V
Adjustment range short-term delayed short-circuit release0 - 0A
Rated permanent current Iu70A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Type of control elementRocker lever
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Degree of protection (IP)IP20
With switched-off indicatorNo
With integrated under voltage releaseNo
Motor drive optionalNo
Adjustment range undelayed short-circuit release480 - 800A
Number of poles3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB1-AF70-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

70 .. 70A

Rated voltage

440 .. 440V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated permanent current Iu

70A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Type of control element

Rocker lever

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Degree of protection (IP)

IP20

With switched-off indicator

With integrated under voltage release

Motor drive optional

Adjustment range undelayed short-circuit release

480 .. 800A

Number of poles

3

Related products