Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage440 - 440V
Rated permanent current Iu90A
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitFrame clamp
Overload release current setting90 - 90A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release600 - 1000A
With integrated under voltage releaseNo
Type of control elementRocker lever
Motor drive integratedNo
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive optionalNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB1-AF90-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

440 .. 440V

Rated permanent current Iu

90A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Frame clamp

Overload release current setting

90 .. 90A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

600 .. 1000A

With integrated under voltage release

Type of control element

Rocker lever

Motor drive integrated

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive optional

Related products