  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release1500 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Rated voltage440 - 440V
Complete device with protection unitYes
Motor drive integratedNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Integrated earth fault protectionNo
Overload release current setting225 - 225A
Rated permanent current Iu225A
Type of control elementRocker lever
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of poles4
Adjustment range undelayed short-circuit release6 - 10A
Type of electrical connection of main circuitFrame clamp
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-4-AF225-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

1500 .. 2500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Rated voltage

440 .. 440V

Complete device with protection unit

Motor drive integrated

With switched-off indicator

Position of connection for main current circuit

Front side

Motor drive optional

Integrated earth fault protection

Overload release current setting

225 .. 225A

Rated permanent current Iu

225A

Type of control element

Rocker lever

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Adjustment range undelayed short-circuit release

6 .. 10A

Type of electrical connection of main circuit

Frame clamp

Degree of protection (IP)

IP20