Technical specifications

Rated permanent current Iu110A
Rated voltage440 - 440V
Overload release current setting110 - 110A
Adjustment range undelayed short-circuit release750 - 1250A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release0 - 0A
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Integrated earth fault protectionNo
Number of poles3
With switched-off indicatorNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-AF110-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

110A

Rated voltage

440 .. 440V

Overload release current setting

110 .. 110A

Adjustment range undelayed short-circuit release

750 .. 1250A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Motor drive optional

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

0 .. 0A

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Integrated earth fault protection

Number of poles

3

With switched-off indicator

Degree of protection (IP)

IP20

Related products