Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally closed contact0
Rated voltage440 - 440V
Adjustment range undelayed short-circuit release8 - 14A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting0 - 0A
Rated permanent current Iu63A
Motor drive integratedNo
Integrated earth fault protectionNo
Number of poles3
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
With integrated under voltage releaseNo
With switched-off indicatorNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-S63-BT-CNA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally closed contact

0

Rated voltage

440 .. 440V

Adjustment range undelayed short-circuit release

8 .. 14A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Overload release current setting

0 .. 0A

Rated permanent current Iu

63A

Motor drive integrated

Integrated earth fault protection

Number of poles

3

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

With integrated under voltage release

With switched-off indicator