Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu125A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting100 - 125A
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release750 - 1250A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Type of control elementRocker lever
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Number of poles3
With switched-off indicatorNo
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A125-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

125A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

100 .. 125A

Integrated earth fault protection

Adjustment range undelayed short-circuit release

750 .. 1250A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

With integrated under voltage release

Position of connection for main current circuit

Front side

Motor drive optional

Number of poles

3

With switched-off indicator

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

Related products