Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Overload release current setting125 - 160A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release960 - 1600A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitFrame clamp
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Position of connection for main current circuitFront side
Motor drive integratedNo
Complete device with protection unitYes
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A160-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Overload release current setting

125 .. 160A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

960 .. 1600A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Frame clamp

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of poles

3

Position of connection for main current circuit

Front side

Motor drive integrated

Complete device with protection unit

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional

Related products