Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release350 - 350A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated permanent current Iu20A
Integrated earth fault protectionNo
Overload release current setting15 - 20A
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
With integrated under voltage releaseNo
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A20-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release

350 .. 350A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated permanent current Iu

20A

Integrated earth fault protection

Overload release current setting

15 .. 20A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

With integrated under voltage release

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

Degree of protection (IP)

IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.