Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Type of control elementRocker lever
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release320 - 400A
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Overload release current setting32 - 40A
Rated permanent current Iu40A
Complete device with protection unitYes
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A40-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Type of control element

Rocker lever

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

320 .. 400A

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Degree of protection (IP)

IP20

Integrated earth fault protection

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Overload release current setting

32 .. 40A

Rated permanent current Iu

40A

Complete device with protection unit

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Related products