Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release3000 - 3000A
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release250 - 2500A
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Overload release current setting125 - 250A
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Number of poles3
With integrated under voltage releaseNo
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-VE250-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

3000 .. 3000A

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Overload release current setting

125 .. 250A

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Number of poles

3

With integrated under voltage release

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Motor drive integrated

With switched-off indicator

Motor drive optional

Degree of protection (IP)

IP20

Related products