Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Type of control elementRocker lever
Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Motor drive optionalYes
Overload release current setting250 - 250A
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Rated voltage690 - 690V
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release3000 - 3000A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release500 - 2500A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-VEF250-BT-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Motor drive optional

Overload release current setting

250 .. 250A

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

3000 .. 3000A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With under voltage release

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

500 .. 2500A

Related products