Technical specifications

Rated permanent current Iu250A
Overload release current setting250 - 250A
Adjustment range undelayed short-circuit release500 - 2750A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
With integrated under voltage releaseNo
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Number of poles3
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementRocker lever
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AEF250-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Overload release current setting

250 .. 250A

Adjustment range undelayed short-circuit release

500 .. 2750A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Rocker lever

Motor drive optional

Related products