Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Overload release current setting300 - 300A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release600 - 3300A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of poles3
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
With switched-off indicatorNo
Type of electrical connection of main circuitScrew connection

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AEF300-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

300A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Overload release current setting

300 .. 300A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

600 .. 3300A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of poles

3

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

With switched-off indicator

Type of electrical connection of main circuit

Screw connection