Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu300A
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release600 - 3300A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release600 - 3000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of poles3
Type of electrical connection of main circuitScrew connection
Complete device with protection unitYes
With switched-off indicatorNo
Motor drive integratedNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Overload release current setting300 - 300A
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VEF300-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

300A

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

600 .. 3300A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

600 .. 3000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Type of electrical connection of main circuit

Screw connection

Complete device with protection unit

With switched-off indicator

Motor drive integrated

With integrated under voltage release

Position of connection for main current circuit

Front side

Overload release current setting

300 .. 300A

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Related products