Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release800 - 4000A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
With integrated under voltage releaseNo
Rated permanent current Iu400A
Position of connection for main current circuitFront side
Number of poles3
Integrated earth fault protectionNo
Overload release current setting400 - 400A
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of control elementRocker lever
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Adjustment range undelayed short-circuit release800 - 4400A
Degree of protection (IP)IP20
Motor drive optionalYes
Rated voltage690 - 690V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VEF400-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

800 .. 4000A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

With integrated under voltage release

Rated permanent current Iu

400A

Position of connection for main current circuit

Front side

Number of poles

3

Integrated earth fault protection

Overload release current setting

400 .. 400A

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of control element

Rocker lever

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Adjustment range undelayed short-circuit release

800 .. 4400A

Degree of protection (IP)

IP20

Motor drive optional

Rated voltage

690 .. 690V