Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu450A
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Overload release current setting450 - 450A
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release675 - 3150A
Adjustment range undelayed short-circuit release900 - 3600A
Position of connection for main current circuitFront side
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive optionalYes
Complete device with protection unitYes
Number of poles3
Type of control elementRocker lever
Integrated earth fault protectionNo
With integrated under voltage releaseNo
With switched-off indicatorNo
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VEF450-NA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

450A

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Overload release current setting

450 .. 450A

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

675 .. 3150A

Adjustment range undelayed short-circuit release

900 .. 3600A

Position of connection for main current circuit

Front side

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive optional

Complete device with protection unit

Number of poles

3

Type of control element

Rocker lever

Integrated earth fault protection

With integrated under voltage release

With switched-off indicator

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Related products